Magnetic Force Starter CEC1-D series
Application
The industrial plugs, sockets, and connectors produced by CEE have good electrical insulation performance, excellent impact resistance, and dustproof, moisture-proof, waterproof, and corrosion-resistant performance. They can be applied in fields such as construction sites, engineering machinery, petroleum exploration, ports and docks, steel smelting, chemical engineering, mines, airports, subways, shopping malls, hotels, production workshops, laboratories, power configuration, exhibition centers, and municipal engineering.
CEE1-D25 has indicators
CEC1-D series magnetic starter is mainly suitable for AC 50/60Hz, rated voltage 550V circuit, for long-distance connecting and disconnecting circuit and frequent start, control motor, this product has small size, light weight, low power loss, high efficiency, safe and reliable performance.
Product Detail
CEE1-D09 (LE1-D09)
Introducing the CEC1-D series magnetic starter! This advanced piece of electrical equipment is the perfect solution for long-distance connection and disconnection circuits as well as frequent starting and controlling of motors.
Designed to operate on AC 50/60Hz circuits with a rated voltage of 550V, the CEC1-D series magnetic starter is a reliable and efficient piece of equipment that is sure to meet all of your electrical needs. With its small size and light weight, this starter can easily fit into any electrical system, making it perfect for both commercial and industrial applications.
One of the key features of the CEC1-D series magnetic starter is its low power loss and high efficiency. This means that energy consumption is minimized, making it a cost-effective solution for managing your electrical systems. Additionally, this starter boasts a safe and reliable performance, ensuring that your motor is always running smoothly and without any hiccups.
So how exactly does the CEC1-D series magnetic starter work? Essentially, it is a device that creates a magnetic field when an electrical current is passed through it. This magnetic field is then used to activate a switch that controls the flow of electricity to the motor. By controlling the amount of electricity being supplied to the motor, the starter is able to start it up smoothly and efficiently, without any sudden surges or drops in power.
As well as its small size and high efficiency, the CEC1-D series magnetic starter also boasts a number of other benefits. For example, it is incredibly easy to install and maintain, meaning that you won't need to spend a lot of time or money on maintenance and upkeep. Moreover, its compact design means that it can fit into even the tightest of spaces, making it an ideal choice for use in cramped or difficult to access areas.
In conclusion, the CEC1-D series magnetic starter is a fantastic choice for anyone looking for a reliable and efficient way to start and control motors. Its small size, low power loss, high efficiency, and safe and reliable performance make it a perfect solution for a wide range of applications. So why wait? The CEC1-D series magnetic starter is waiting for you – order yours today!
Product Data
Maximum power Ac3 duty(KW) | Rated current current(A) | Class of protection | Code number | Suitable thermal relay | ||||||||||||||
220V
230V |
380V
400V |
415V | 440V | 500V | 660V
690V |
LL(Long life) | NL(3)
Normal life |
|||||||||||
2.2 | 4 | 4 | 4 | 5.5 | 5.5 | 9 | IP42 | CEE1-D094... | CER2-D1312 | |||||||||
IP65 | CEE1-D093... | CER2-D1314 | ||||||||||||||||
3 | 5.5 | 5.5 | 5.5 | 7.5 | 7.5 | 12 | IP42 | CEE1D124... | CEE1-D094... | CER2-D1316 | ||||||||
IP55 | CEE1-D123... | CEE1-D093... | ||||||||||||||||
4 | 7.5 | 9 | 9 | 10 | 10 | 18 | IP42 | CEE1-D188... | CEE1-D124... | CER2-D1321 | ||||||||
IP55 | CEE1-D185... | CEE1-D123... | ||||||||||||||||
5.5 | 11 | 11 | 11 | 5 | 15 | 25 | IP42 | CEE1-D258.. | CEE1-D188... | CER2-D1322 | ||||||||
IP55 | CEE1-D255... | CEE1-D185... | CER2-D2353 | |||||||||||||||
7.5 | 15 | 15 | 15 | 18.5 | 18.5 | 32 | IP55 | CEE1-D325.. | CEE1-lD255... | CER2-D2355 | ||||||||
11 | 18.5 | 22 | 22 | 22 | 30 | 40 | IP55 | CEE1-D405... | CEE1-D325... | CER2-D3353 | ||||||||
CER2-D3355 | ||||||||||||||||||
15 | 22 | 25 | 30 | 30 | 33 | 50 | IP55 | CEE1-D505... | CEE1-D405.. | CER2-D3357 | ||||||||
CER2-D3359 | ||||||||||||||||||
18.5 | 30 | 37 | 37 | 37 | 37 | 65 | IP55 | CEE1-D655.. | CEE1-D505... | CER2-D3361 | ||||||||
22 | 37 | 45 | 45 | 55 | 45 | 80 | IP55 | CEE1-D805... | CEE1-D655... | CER2-D3363 | ||||||||
CER2-D3365 | ||||||||||||||||||
25 | 45 | 45 | 45 | 55 | 45 | 95 | IP55 | CEE1-D955... | CEE1-D805... | CER2-D3365 | ||||||||
Enclosure | CEE1-N09 and N12 | Double insulation, protection class is IP42 | ||||||||||||||||
CEE1-N18 andN25 | Double insulation, protection class is IP427 | |||||||||||||||||
CEE1-N32 N95 | Metal IP55 to JR 559 | |||||||||||||||||
The control 2 button is mounted on the housing cover | CEE1-N09 N95 | 1 green start button "l"
1 red stop/reset button "O" |
||||||||||||||||
The connection | CEE1-N09 N95 | Pre-wired power and control circuit connections | ||||||||||||||||
Standard control circuit voltages | ||||||||||||||||||
Volts | 24 | 42 | 48 | 110 | 220/230 | 230 | 240 | 380/400 | 400 | 415 | 440 | |||||||
50/60Hz | B7 | D7 | E7 | F7 | M7 | P7 | U7 | Q7 | V7 | N7 | R7 |